Product Descriptions
Metriso Xtra 1000V Insulation Tester
Test Instrument for Insulation, Low-resistance and Voltage Measurements - with Memory
Compact and rugged - for service calls under harsh conditions and laboratory use
The METRISO XTRA insulation and resistance measuring instruments allow for quick and effective testing of protective measures in accordance with:
DIN VDE 0100
ÖVE-EN 1 (Austria)
SEV 1000 (Switzerland)
and regulations specific to other countries as well
Insulation measurement per EN 61557-2 / VDE 0413 part 2
Low-resistance measurement per EN 61557-4 / VDE 0413 part 4
Voltage testing and measurement up to 1000 V
Applications
- The insulation measuring instruments are suitable for the following tasks:
 
- Measurement of insulation resistance at voltage-free devices and systems, up to 1000 V
 
- Testing of the resistance of earthing conductors, protective conductors and equipotential bonding
 
- Checking of test objects for absence of voltage
 
- Testing of electrostatic discharge capacity at floor coverings (using shielded measurement cables) - EN 1081
 
- With the so-called 1 mA test per DIN VDE 0845/EN 61645, the instrument also allows to perform on-site tests of the response voltage of overvoltage components (varistors, Zener diodes, etc.) of requirement categories B and C / SPD Type 2 and 3) and to evaluate the test results in accordance with manufacturer‘s data.
 
Technical characteristics
- Test voltages in fixed increments, variable or as a ramp 50, 100, 250, 500, 1000 V
 
- Polarization index and absorption ratio
 
- Intelligent filter - precise and measurement-dependent activation for the measurement of very high resistances - beating, i. e. compensation of 16 2/3 Hz and 50 Hz interference - attenuation of capacitive influences from power cables, etc. - suppression of electric field influences
 
- Signalling of dangerous contact voltage
 
- Acoustic signalling when limit value is exceeded
 
- Detection of interference voltage in switch position OFF
 
- Overvoltage protection - protects the instrument in the event of inadvertent connection to mains power
 
- Fuse link for all resistance measuring ranges
 
- New: Electronic fuse for protection of the low-resistance measurement RLO also protects the fuse link in the low-resistance measuring range in the event of faulty operation
 
- One measuring point self-test with test resistance of 10 MΩ per EN 50110 / VDE 0105-100
 
- Backlit dot matrix display for measured and limit values
 
- Timer function 1 s ... 100 min
 
- Guard terminal for compensating surface current
 
Measurements
- PI, DAR Polarization index measurements
 
- Riso Uvariable = 50 ... 1000 V (Limit value 1 MΩ)
 
- Riso URamp = 50 ... 1000 V Display of breakdown voltage
 
- Measuring ranges Riso 10 k ...1 TΩ
 
- Riso U = 50, 100, 250, 500 / 1000 V
 
- R 10 Ω... 10 kΩ
 
- RLO 0,01 ... 10 Ω
 
- U 0 ... 500 / 1000 V
 
Display functions
- Backlit display
 
- Limit value LED Limit (green/red) Additional acoustic signal, limit value per VDE 0100 Riso, RLO
 
- LED for dangerous contact voltage (when switched off)
 
- LCD symbol for external voltage
 
- Battery level display
 
Special functions
- Data storage in the instrument, 50.000 objects
 
- Discharge capacitive devices under test
 
- Safety shutdown (UBatt < 8 V)
 
Features
- Charging socket, RS232 and USB interface
 
- Measuring categories CAT II 1000V, CAT III 600V
 
- Measuring category CAT III 600V, CAT IV 300V
 
- Integrated 10 MΩ test resistor
 
- DAkkS calibriation certificate in scope of delivery
 
Delivery
- Insulation and resistance measuring instrument
 
- DAkkS calibration certificate
 
- Set of batteries
 
- Carrying strap
 
- Alligator clip
 
- Cable set KS17-4
 
- USB cable
 
- Condensed operating instructions
 
- Supplement Safety Information
 
 
Product Code: M550S